Overview
Product name
Human Cardiac Troponin I ELISA KitSee all Cardiac Troponin I kitsDetection method
ColorimetricPrecision
Intra-assay Sample n Mean SD CV% Human heart 8 3% Inter-assay Sample n Mean SD CV% Human heart 3 7.1% Sample type
Cell culture supernatant, Serum, Cell culture extracts, Tissue Extracts, Hep Plasma, EDTA Plasma, Cit plasmaAssay type
Sandwich (quantitative)Sensitivity
4.4 pg/mlRange
31.3 pg/ml -4000 pg/mlRecovery
Sample specific recovery Sample type Average % Range Serum 97 93%- 101% Tissue Extracts 112 104%- 118% Cell culture media 102 97%- 108% Hep Plasma 107 99%- 117% EDTA Plasma 93 90%- 97% Cit plasma 93 87%- 100% Assay time
1h30mAssay duration
One step assaySpecies reactivity
Reacts with:HumanProduct overview
As of November 7, 2018, Human Cardiac Troponin 1 ELISA kit has been re-developed. We have identified new recombinant monoclonal antibodies to provide improved performance and consistency.
Human Cardiac Troponin I ELISA Kit (ab200016) is a single-wash 90 min sandwich ELISA designed for the quantitative measurement of Cardiac Troponin I protein in serum, tissue extracts, cell culture extracts, hep plasma, cit plasma, edta plasma, and cell culture supernatant. It uses our proprietary SimpleStep ELISA® technology. Quantitate Human Cardiac Troponin I with 4.4 pg/ml sensitivity.
SimpleStep ELISA® technology employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step, significantly reducing assay time. See the SimpleStep ELISA® protocol summary in the image section for further details. Our SimpleStep ELISA® technology provides several benefits:
- Single-wash protocol reduces assay time to 90 minutes or less- High sensitivity, specificity and reproducibility from superior antibodies- Fully validated in biological samples- 96-wells plate breakable into 12 x 8 wells strips
A 384-well SimpleStep ELISA® microplate (ab203359) is available to use as an alternative to the 96-well microplate provided with SimpleStep ELISA® kits.
Notes
The regulatory troponin complex regulates skeletal and cardiac muscle contraction. This complex, together with tropomyosin, is located on the actin filament and it is composed of three protein subunits: troponin T (the tropomyosin-binding subunit), troponin I (the inhibitory subunit, which inhibits the ATPase activity of acto-myosin), and troponin C (the Ca2+-binding subunit). Troponins T and I have unique cardiac isoforms, whereas cardiac and skeletal muscle share troponin C. Specifically, three human troponin I isoforms have been described: one is expressed in cardiac muscle (Cardiac Troponin I) and the other two are found in slow-twitch and fast-twitch skeletal muscle fibers (slow sTnI and fast sTnI, respectively). The sequence homology between Cardiac Troponin I and slow sTnI is approximately 40% and somewhat less for fast sTnI. Cardiac Troponin I is 209 amino acid long with a molecular weight of approximately 24 kDa. Mouse and rat Cardiac Troponin I proteins both show 93% amino acid identity to human Cardiac Troponin I. The presence of human Cardiac Troponin I in serum (together with chest pain and electrocardiographic changes) is now considered as one highly specific biochemical marker of myocardial injury, risk stratification of acute coronary syndrome and myocardial infarction. Mutations of Cardiac Troponin I are associated with hereditary cardiomyopathy. Specifically, defects in Cardiac Troponin I are the cause of cardiomyopathy familial hypertrophic type 7 (CMH7). Familial hypertrophic cardiomyopathy is a hereditary heart disorder characterized by ventricular hypertrophy, which is usually asymmetric and often involves the interventricular septum. The symptoms include dyspnea, syncope, collapse, palpitations, and chest pain. They can be readily provoked by exercise. The disorder has inter- and intra-familial variability ranging from benign to malignant forms with high risk of cardiac failure and sudden cardiac death. Defects in Cardiac Troponin I also cause cardiomyopathy familial restrictive type 1 (RCM1). RCM1 is a heart muscle disorder characterized by impaired filling of the ventricles with reduced diastolic volume, in the presence of normal or near normal wall thickness and systolic function. Furthermore, cardiomyopathy dilated type 2A (CMD2A) and cardiomyopathy dilated type 1FF (CMD1FF), disorders characterized by ventricular dilation and impaired systolic function resulting in congestive heart failure and arrhythmia, are caused by defects in Cardiac Troponin I.
Abcam has not and does not intend to apply for the REACH Authorisation of customers’ uses of products that contain European Authorisation list (Annex XIV) substances.It is the responsibility of our customers to check the necessity of application of REACH Authorisation, and any other relevant authorisations, for their intended uses.
Platform
Microplate (12 x 8 well strips)
Properties
Storage instructions
Store at +4°C. Please refer to protocols.Components 1 x 96 tests 10X Human Cardiac Troponin I Capture Antibody 1 x 600µl 10X Human Cardiac Troponin I Detector Antibody 1 x 600µl 10X Wash Buffer PT (ab206977) 1 x 20ml 5X Cell Extraction Buffer PTR (ab193970) 1 x 10ml Antibody DiluentCPI - HAMA Blocker (ab193969) 1 x 6ml Human Cardiac Troponin I Lyophilized Recombinant Protein 2 vials Plate Seals 1 unit Sample Diluent 50BP 1 x 20ml Sample Diluent NS (ab193972) 1 x 50ml SimpleStep Pre-Coated 96-Well Microplate (ab206978) 1 unit Stop Solution 1 x 12ml TMBDevelopment Solution 1 x 12ml Cellular localization
Cytosol; Sarcomere.Alternative names
- Cardiomyopathy dilated 2A (autosomal recessive)
- CMD1FF
- CMD2A
see allDatabase links
- Entrez Gene:7137 Human
- Omim:191044 Human